Temperature & Power Control FAQ

Answers to common engineering questions on PID outputs, SSR/SCR selection, heatsink sizing, and sensor matching.

When should I choose an SSR vs. an SCR power regulator?

Use a Solid State Relay (SSR) for on/off or fast-cycle PID time-proportional control on resistive loads typically from 10A to 100A. Choose an SCR power regulator when you need smooth continuous 4-20mA / 0-10V phase-angle or zero-crossing power regulation, soft-start for transformer/low-resistance heaters, or high three-phase currents up to 400A.

How do I size an SSR and heatsink for my heater load?

Divide heater power (W) by supply voltage (V) to obtain load current, then apply a safety derating factor (typically 2x for resistive loads, higher for inductive or high-ambient panels). Every SSR above 10A requires an appropriately sized aluminum heatsink and thermal compound or thermal pad.

Which thermocouple or RTD sensor should I pair with my PID controller?

K-type (WRN) covers general industrial heating up to 1200°C, J-type is common in plastics and molding up to 750°C, and Pt100 (WZP) RTDs offer higher precision and stability for lower-temperature processes such as food fermentation and drying.

Can Kirmer supply pre-matched temperature control kits?

Yes. We assemble complete PID + SSR/SCR + Thermocouple + Heatsink kits grouped by power band (<4 kW, 4-15 kW, and >15 kW) so all signals, current ratings, and thermal margins match out of the box.

Request a Proposal

Need a matched temperature & power control quote?

Share your heating load (kW / A), supply voltage (1-phase / 3-phase), sensor type (K / J / Pt100), or panel cutout size. Our engineering team responds within 24 hours with a matched KR- series proposal.